Virtual Multimeter & Oscilloscope (Simulator Instruments)

When running projects inside the circuit simulator, virtual diagnostic instruments provide non-intrusive signal measurement.

Digital Multimeter

At a glance

Pins and properties exactly as the circuit editor and simulator define this part. The text below explains how to use them.

Pinout

Pinout of the Digital Multimeter, drawn as in the circuit editor. Select a label to see that pin in the table below.

Pins

Pins of this part
PinLabelType
V_OHMV/ΩBidirectional
COMCOMBidirectional
AMPS10ABidirectional

Properties

What you can change in the Property Inspector.

Properties of this part
PropertyRange or choicesDefault
Measurement ModeOFF, DC Voltage, Resistance, DC CurrentOFF

When running projects inside the circuit simulator, virtual diagnostic instruments provide non-intrusive signal measurement.

1. Virtual Digital Multimeter (multimeter.ts)

The simulator features a 3.5-digit autoranging Digital Multimeter (DMM):

       ┌──────────────────────────────┐
       │   DC    AUTO      24.5  mV   │  <- Backlit Cyan LCD Screen
       └──────────────────────────────┘
                    ( (O) )              <- 4-Position Rotary Selector Dial
                 /   │   \   \
               OFF   V⎓   Ω   A⎓
  • Measurement Modes & SPICE Models:
    • DC Voltage (V⎓V\text{⎓}): High-impedance 10 MΩ10\text{ M}\Omega parallel probe across V/Ω and COM pins. Measures node voltage differential: Vdiff=VV/Ω−VCOMV_{\text{diff}} = V_{\text{V/Ω}} - V_{\text{COM}}
    • DC Current (A⎓A\text{⎓}): Low-resistance 0.05 Ω0.05\text{ }\Omega shunt resistor inserted in series across 10A and COM pins. Measures branch current: Isense=V10A−VCOM0.05 ΩI_{\text{sense}} = \frac{V_{\text{10A}} - V_{\text{COM}}}{0.05\text{ }\Omega}
    • Resistance (Ω\Omega): Applies a 1 μA1\ \mu\text{A} internal test current source (Itest=1⋅10−6 AI_{\text{test}} = 1\cdot 10^{-6}\text{ A}) and 100 MΩ100\text{ M}\Omega protection bleed resistor across V/Ω and COM. Calculates resistance: Rmeasured=VV/Ω−VCOM1⋅10−6 AR_{\text{measured}} = \frac{V_{\text{V/Ω}} - V_{\text{COM}}}{1\cdot 10^{-6}\text{ A}}
      • Overflow Handling: Displays "O.L" (Over Limit) when measured resistance exceeds 19.99 MΩ19.99\text{ M}\Omega.
    • OFF: High-impedance 1 GΩ1\text{ G}\Omega isolation state.

2. Virtual Oscilloscope

  • Signal Probe: Probes simulated GPIO pins to display real-time voltage vs time waveforms.
  • PWM Analysis: Measures frequency (Hz\text{Hz}) and duty cycle (%\%) of PWM output pins.
  • Digital Logic Transitions: Captures high-speed digital state changes.

3. Overvoltage & Short-Circuit Fault Warnings

  • Overvoltage Clamping: Emits visual warning overlays when an input pin exceeds supply rail voltage plus tolerance (VGPIO>VCC+0.2VV_{\text{GPIO}} > V_{\text{CC}} + 0.2\text{V}).
  • Short-Circuit Warnings: Highlights short-circuit paths where power pins connect directly to ground without current-limiting load resistance.
Virtual Multimeter & Oscilloscope (Simulator Instruments) — OMS Parts